Duerkopp Adler 579 Operations Instructions Page 70

  • Download
  • Add to my manuals
  • Print
  • Page
    / 85
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 69
33.17 Output Test
ATTENTION !
The turning-on of output elements can lead to collisions with other
machine elements and to damage to the automatic sewing machine.
Before any output element is turned on make sure that this cannot
collide with other components of the automatic sewing machine.
One can switch individual or several outputs in this menu.
When you are in the service menu, sequentially select the following
menu items with the arrow keys and the OK key:
- Test Functions
- Multitest
- Output Test
The Output Test menu appears.
Select the desired output with the up and down arrow keys. The
current status of the output is shown behind the output number:
- = Output not activated
+ = Output activated
Press the OK key.
The output is switched over.
With output Y16 (knife), a warning appears.
Press the OK key. The knife is switched.
Output Designation
Y1 Cloth clamps
Y2 Spread the material
Y3 Needle thread tension
Y4 Needle thread gripper
Y5 Draw forward the needle thread
Y6 Needle thread trimmer
Y7 Open the looper thread tension and draw thread forward
Y8 Looper thread trimmer depending on subclass
Y9 Needle thread catcher
Y10 Looper thread trimmer with subclass
579-121000 and 579-141000
Y11 Needle thread catcher gripper
Y12 Needle thread catcher swings to the needle
Y16 Cutting buttonholes