Duerkopp Adler 579 Operations Instructions Page 63

  • Download
  • Add to my manuals
  • Print
  • Page
    / 85
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 62
33.15 Setting the Times
The various time intervals which control the sewing cycle can be set in
this menu. The values in brackets are the default values.
ATTENTION !
Change this setting only after consultation with DÜRKOPP ADLER.
When you are in the service menu, sequentially select the following
menu items with the arrow keys and the OK key:
- Configuration
- Times
The Times menu appears.
Select the time interval to be changed with the arrow keys.
Press the OK key.
Change the value for the time with the arrow keys.
Press the OK key.
T0 (Cutting a
buttonhole)
Standard: 40
Setting range: 0-100
- Cutting the buttonhole
- Contact
- The interval T0 is run through.
- The stamp moves upward
Care must be taken to see that the buttonhole is cut open along its whole
length.
T1 (Thread catcher)
Standard: 20
Setting range: 0-100
- The thread gripper of the needle thread catcher is closed (valve Y11)
- The interval T1 is run through
- The needle thread catcher swings away from the needle (valve Y12)
Care must be taken that the needle thread is clamped before the needle
thread catcher swings back.
T2 (Thread catcher)
Standard: 20
Setting range: 0-100
- The needle thread catcher swings away from the needle (valve Y12)
- The interval T2 is run through
- The needle thread catcher moves upward (valve Y09)
Care must be taken that the thread gripper is no longer under the needle
before the needle thread catcher runs upward.
T3 (Idle period)
Standard: 120
Setting range: 0-200
- The buttonhole is cut open
- Contact is triggered
- The interval T3 is run through
- The cloth support plate moves.
Care must be taken that the cutting stamp is raised before the cloth support
plate runs forward.