Duerkopp Adler 271 Instruction Manual

Browse online or download Instruction Manual for Sewing machines Duerkopp Adler 271. Duerkopp Adler 271 Instruction manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
AC SERVO MOTOR
INSTRUCTION MANUAL FOR DŰRKOPP ADLER-271 MACHINE ONLY
Please read this manual thoroughly before use to ensure safe and proper use.
Please read the instruction manual for the machine head together with this manual.
Save this manual for future reference.
HVP-70-4-ED FOR DŰRKOPP ADLER- 271
HSVP70U01 - EN 2006. 08
ENGLISH
MINI-MOTOR TYPE
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - ENGLISH

AC SERVO MOTOR INSTRUCTION MANUAL FOR DŰRKOPP ADLER-271 MACHINE ONLY Please read this manual t

Page 2 - Contents

- 7 -P S A B C D LOGO Remove 4 screws(5). How to supply an additional power source from the control box :

Page 3

- 8 -4. Diagrams Of Control Box : (1). Front side : (2). Rear side : Connector Panel (Model:HVP-70-4-ED) DC12V

Page 4 - 1. Safety Precaution

- 9 -STOPP SA B C D.End Back-Tacking ON / OFF Number of Stitches setting( range 0 ~ F ) * A =10stitch….F=15stitch Start Back-Tacking ON / OFF Presse

Page 5 - High Voltage Inside

- 10 -Remark: In【Mode A 】First parameter showing is【0 0 1. H 】. All available parameter start from 1 ~ 46. In

Page 6 - Control

- 11 -No Function LED for start Constant stitch sewing (ON: LED light) Presser Foot goes Up / down after trimmingParameter key Saving key Presser

Page 7

- 12 -6. How to enter parameter mode : (1). How to enter【Normal Mode】level : (2). How to enter 【Parameter Mode】level : Parameter Mode

Page 8 - Green/Yellow wire

- 13 -(3). How to set the Parameter Value : Note 1: Confirm the parameter code you want to adjust. (See the parameter table for detail) Note 2:

Page 9 - Remove 4 screws

- 14 -7.How to adjust Needle position : For DURKOPP ADLER - 271 Needle position adjustment illustration OPERATION

Page 10 - Recommend use PVC cable

- 15 - b. Press and hold keys, then turn ON the power. LED will display【 RESE T】and blink twice. A BP S STOPP SA B C D STOPP SA B C D8. Ho

Page 11 - 4. Diagrams Of Control Box :

- 16 -9. Basic troubleshooting : (1). Error Code and Measurement : Error Code Cause of The Problem Status and Measurement ER0. 1 1. Power module det

Page 12 - Constant Stitch 】sewing

1. Safety Precaution 1.1 Work environment ……………………………………………………………………………………… 1.2 Safety in installation ………………………………………………………………………………

Page 13 - Value 』area

- 17 -Error CodeCause of The Problem Status and Measurement ER0. 9 1. Machine solenoid shorted. 2. Main board’s power transistor is faulty. Motor s

Page 14 - No Half Heeling Function

- 18 -(2). Instruction of Fuse Replacement : (3). Others : . 1. During the machine’s operation, if the synchronize

Page 15 - 3 phase type

- 19 -(4). PARTS LIST : HVP-70-4-ED for DŰRKOPP ADLER -271 only Motor Parts: Control Box Parts : Speed Control Unit :

Page 16 - 0 to 9 。

- 20 -Main Parts List of HVP-70-4-ED : ITEM PART CODE PART NAME SPEC. 1 2VP3432209AX7 Motor Ass. (CE) Ke:28 500W (VP-50AB104-CE) 1-1 2VPPBE01

Page 17 - Display【176.VDN】

- 21 -10. Operation Box : (1).Operation Box Diagram : (2). Key Functions : FUNCTION KEY OPERATION OF SEWING MACHINE Single start back t

Page 18 - Lockstitch

- 22 - Stitch Setting Selection A、B、C、D -- stitch setting range in 0 ~ F (Note) E、F、G、H -- stitch setting range in 0 ~ 99

Page 19 - 9. Basic troubleshooting :

- 23 -11.HVP - 70 - 4 - ED PANEL : 1916- O7 ML6+ 12V111O4 (16- O12) FSPR LEDNFD LED+24VHP LEDZVR LED16- O916

Page 20

- 24 -NAME DIRECTIONS NAME DIRECTIONS ZVR Intermediate backtack R-SELEKT Resistor for machine select NHT Needle up / down R-N-HP Set po

Page 21 - Main Board Top View

PAGE 1software version : D2.8(FOR HVP70-4-ED only)100 ohm 220 ohm 680 ohm 1000 ohm2200 ohmUSER1HMaximum sewing speed50 - 9999 spm 4800 900 1700 3500 6

Page 22

PAGE 2software version : D2.8(FOR HVP70-4-ED only)100 ohm 220 ohm 680 ohm 1000 ohm2200 ohmDescriptionRangeParameters FunctionParametersCodePreset ForH

Page 23

7. How to adjust Needle position ………………………………………………………… 8. How to use【Recovery】to go back at factory default ……………… 9. Basic Troubleshooting (1).

Page 24

PAGE 3software version : D2.8(FOR HVP70-4-ED only)100 ohm 220 ohm 680 ohm 1000 ohm2200 ohmDescriptionRangeParameters FunctionParametersCodePreset ForH

Page 25 - ~ 99

PAGE 4software version : D2.8(FOR HVP70-4-ED only)100 ohm 220 ohm 680 ohm 1000 ohm2200 ohmDescriptionRangeParameters FunctionParametersCodePreset ForH

Page 26 - DC12V 50 mA

PAGE 5software version : D2.8(FOR HVP70-4-ED only)100 ohm 220 ohm 680 ohm 1000 ohm2200 ohmDescriptionRangeParameters FunctionParametersCodePreset ForH

Page 27

PAGE 6software version : D2.8(FOR HVP70-4-ED only)100 ohm 220 ohm 680 ohm 1000 ohm2200 ohmDescriptionRangeParameters FunctionParametersCodePreset ForH

Page 28

PAGE 7software version : D2.8(FOR HVP70-4-ED only)100 ohm 220 ohm 680 ohm 1000 ohm2200 ohmDescriptionRangeParameters FunctionParametersCodePreset ForH

Page 29

PAGE 8software version : D2.8(FOR HVP70-4-ED only)100 ohm 220 ohm 680 ohm 1000 ohm2200 ohmDescriptionRangeParameters FunctionParametersCodePreset ForH

Page 30

PAGE 9software version : D2.8(FOR HVP70-4-ED only)100 ohm 220 ohm 680 ohm 1000 ohm2200 ohmDescriptionRangeParameters FunctionParametersCodePreset ForH

Page 31

PAGE 10software version : D2.8(FOR HVP70-4-ED only)100 ohm 220 ohm 680 ohm 1000 ohm2200 ohmDescriptionRangeParameters FunctionParametersCodePreset For

Page 32

PAGE 11software version : D2.8(FOR HVP70-4-ED only)100 ohm 220 ohm 680 ohm 1000 ohm2200 ohmDescriptionRangeParameters FunctionParametersCodePreset For

Page 33

PAGE 12software version : D2.8(FOR HVP70-4-ED only)100 ohm 220 ohm 680 ohm 1000 ohm2200 ohmDescriptionRangeParameters FunctionParametersCodePreset For

Page 34

- 1 -1. Safety Precaution When install and operate HVP-70 MINI Servo Motor, precaution must be taken as the following. This product is

Page 35

7-Segment Display Characters Compare Chart : Arabic Numerals Actual Numbers 0 1 2 3 4 5 6 7 8 9 Display Numbers English Alphabet Actual

Page 36

- 2 -b. Use the correct connector and extension wire when connecting ground wire to Earth and secure it tightly. 1.3 Safety in Operating:

Page 37

- 3 -Control box PABCLOGO80 mm300 mm300 mm 270 mm DURKOPP ADLERGEHFABCD2. Installation and Adjustment: (1).Motor Installation : (2).Control

Page 38

- 4 -(5). Adjust the force required to operate the foot pedal : BA CDless more less more Components of the speed control unit: see

Page 39

- 5 -3. Power Connection and Grounding : (1). Single phase and three phase connection : Green/yellow wire is the ground wire.

Page 40

- 6 -(3). When using 1Φ / 220V motors in 3Φ / 220V power system, please make power connections as below for load balance. (4). How to change